While using a wire fill table for electrical conduit it is best to size the conduit up to the next incremental size to be sure the conduit is not overfilled and it will make pulling in.
Emt pipe wire capacity.
The results show the allowable number of wires for each size type of conduit and wire based on the 2020 nec code.
Helps determine the proper wire size for an electrical circuit based on the voltage drop and current carrying capacity of an electrical circuit.
This online conduit fill calculator is compatible with the us national electrical code nec.
Inch emt has a maximum fill of 0 122 which is too small.
For example to use emt type conduit with the previously calculated total fill of 0 138 look in the emt column of table 4.
If you re using electrical metal tubing emt conduit you ll see that the closest size that you need is a 1 in conduit which gives you a 39 fill.
Welcome to the conduit fill calculator website.
If you have a fixed conduit type and size.
Conduit fill calculator conduit fill is the percent of area inside the conduit taken up by the cable s.
Each column going up and down is a different gauge of wire.
However inch emt has a maximum fill of 0 213 which is greater than the 0 138 calculated fill.
Electrical conduit whether it be rigid metal emt rigid plastic pvc or flexible metal fmc is limited as regards the maximum number of electrical wires that can be run inside the conduit.
Using electrical conduit is the required method of protecting electrical wires in exposed situations where nm cable cannot be used.
Just select the conduit type and the wire insulation to get a quick table of conductor properties.
The amount of wire fill inside a conduit must be configured properly to prevent overheating of the wire which is why conduit fill tables are very important.
Provides quick and easy results for the conduit fill percent per nec guidelines.
We hope to provide you with the best online conduit fill calculator as well as all relevant information regarding conduits conduit fill conduit accessories and more.
Conduit cable fill chart this chart for conduit size for cable is based on the 2017 nec and uses common conduit types and wires.
The pvc conduit fill table.
Inch conduit is the correct size for this application.
Trade size wire size thwn thhn conductor size awg kcmil 14 12 10 8 6 4 3 2 1 1 0 2 0 3 0 4 0 250 300 350 400 500 600 700 750 1 2 emt 12 9 5 3 2 1 1 1 1 1 imc 14 10 6 3 2 1 1 1 1 1 1 grc.
Find the type of conduit that you want to use in table 4.
The possible wire gauges go from 14 awg to 750 mcm and from conduit trade sizes of 1 2 inches to 4 inches.