Trust eaton s emergency lighting upss 10 200 kva to keep your occupants safe and your.
Emergency lighting ups requirements.
In addition to prioritizing safety proper emergency lighting is required by building codes such as nfpa 101 the life safety code.
Lighting emergency lighting requirements and related building codes such as the life safety code nfpa 101 are vital in the construction of commercial structures to facilitate safe occupant exit during a building fire or other emergency situation.
One of the best solutions is to use a central uninterruptible power supply providing power to these critical safety systems in accordance with these standards.
Nfs 61 940 france only and en 50171.
These are traditionally shaped much like a lunchbox and thus are sometimes called lunchboxes in the field.
A ups serving as the emergency power source must comply with the applicable requirements for batteries and generators.
This section specifies the requirements for how bright emergency lighting must be and how long it must be provided in the event of failure of normal lighting.
When specifying a ups uninterruptible power supply for emergency lighting applications a static inverter will be used to maintain power to lighting for a period of 1 hour or 3 hours depending on specification as per en 50171 2001.
In the first 1 5 hours after a failure emergency lighting must provide an average of one foot candle and no less than 0 1 foot candle at any point along the path of egress.
Staco energy products emergency lighting ups systems are a result of your demand for an emergency lighting solution tailored to meet your requirements for reliable cost effective alternative for emergency lighting applications that ensure the safety of your most import asset your people.
Ul924 emergency lighting central inverter ups systems are different than other mission critical power systems in that their application is designed for life safety in emergency situations.
Where unit equipment is not used for emergency illumination or is not the sole source of emergency illumination an additional source of electrical power may be provided using an uninterruptible power supply ups a generator a fuel cell or a separate service used to supply emergency lighting.
Emergency lighting system shall be capable of maintaining the stipulated lighting level for a period of not less than 1 hour with power supplied either from a dedicated uninterruptible power supply ups system or from a central battery dc supply system.
Or ii for cinemas theatres premises accommodating more than 500 persons the.
Bs en 50171 2001 specifies the requirements for how long emergency lighting is on how bright it is and more.
By individual unit equipment iue the nec means an emergency lighting battery pack 700 12 f.
Eaton s emergency lighting ups systems are ul 924 tested and certified providing you.